Main Menu

 

mini - PACCS Personal duress alarm system

 

The mini - PACCS “man-down” is a microprocessor-controlled personal emergency transmitter designed for use by guards and security officers in prisons and institutions, or by people working alone in industrial and other high-risk facilities. The mini - PACCS has five types of events: Distress – by depressing the two emergency buttons simultaneously, man-down – when the wearer falls down, pull-cord – when someone attempts to pull the transmitter off the wearer, test – for testing the transmitter and tamper – when an unauthorised person opens the transmitter.

For maximum security, the Mini - PACCS uses a unique, factory programmed, randomly selected 24-bit digital alarm ID code during each transmission. This code is selected from 16 million possible code combinations and is therefore unique and virtually impossible to accidentally reproduce. A smart anti-collision algorithm prevents signal jamming by simultaneous transmission from multiple devices.

The fully supervised repeater issues a test report on an hourly basis, indicating faults such as power failure, low battery charge and tampering.

The mini - PACCS can be integrated into any alarm system, or paging system, and it supports an exceptionally wide range of detection devices.
In case an event is detected, mini - PACCS automatically issues a report to the monitoring station, simultaneously transmitting digital and voice alerts to pre-programmed private telephones, mobile phones and/or pagers. All this functionality is packed into a single wireless solution, which is as easy to deploy as it is to operate.

The mini - PACCS wireless system is ideal for SME’s and SoHo applications, as well as industrial, processing and medical sites and is easily installed, being set up as pre-configured to work out of the box.

 

 

SPECIFICATIONS

mP-Belt T( Man Down Transmitter)

Transmission Type: Radio Frequency (RF)
RF Frequency (MHz): 315MHz, 418 MHz or 433.92 MHz
Transmitter s ID Code: 20- bit ID 4 –bit Event ID
Modulation Type: Pulse width modulation
Over all message length: 36 bit
Alarm messages: Tilt activated, pull- cord disconnected, panic alarm, Test, each with separate ID
Supervision: Option for automatic reporting at I – hour intervals
Power Source: 3.6 v, lithium battery, size ½ AA/ 1.2 Ah, ( Tadiran TL – 2150 or equivalent)
Current Consumption: 15µ A standby, 10Ma ( Operation).
Battery Life: 3- 4 years in normal use
Battery supervision: Battery test and reporting every hour
Operating temperature: 0º C to 49º C ( 32º F to 120ºF)
Dimensions ( H X WX D): 120 X 52 X 36 MM ( 4-3/4X 2-1/16 X1-5/16in.)
With holster-3: 140 x 77 x 50 mm ( 5-7/16 x3-1/16 x1 -15/16 in.)
Housing: 3mm ABS PLASTIC BOX, Weather proof
Weight: Man – down – 138g ( 4.9 Oz.) Holster -3 -30g (1.05 0z.)
Color: Body – dark gray, buttons – brown, pull cord – black

Compliance with Std: FCC part 15, CE ( ETS 300220, ETS 300683)
Accessories: light weight water – resistant carry pouch holster -3. metal belt clip.
Pull cord with pin and cloth clip.

 

 

SPECIFICATIONS

mP-Receiver 8: Wireless interface for Hard wire control panels


RF SECTION
Front end module: Super heterodyne UHF Receiver.
Operating frequency ( MHz) : 315, 418 , 433.92, 868.95 and other UHF channels per local requirements in country of use.


DATA PROCESSING SECTION
ID Codes: over 16,000,000 possible 24- bit combinations
Total Message Length: 36bits(66 bits for code secure devices)
ID learning capacity: 112 different ID Codes
Expander Bus: 4 wires (12V+, (-), DATA and COMMON)


ELECTRICAL DATA
Zone outputs: 4, up to 100mA each, open- collector type
Status outputs: 4, up to 100Ma each, open – collector type
Output No .1 Modes: pulsed ( 2 seconds) or toggle, selected with DIP switch
Output Polarities: N.0 or N.C., Selected with DIP Switch
Tamper Switch Ratings: 0.1A/30VDC.
Input Voltage Range: 10.5 – 16VDC
Current Drain ( @ 12 VDC): 45Ma


PHYSICAL
Operating Temperatures: 0º C to 49ºC ( 32º ì F to 120º ì F).
Dimensions ( H X W XD): 108 X 165 38 mm (4 – ¼ x 6-1/2 x 1-1/2”)
Weight ( Including rigid antenna): 214g ( 7.5oz).
Compliance with standards: Meet FCC part 15, ETS 300-220, ETS 300- 683 and MPT 1340 requirements


AUXILIARY EQUIPMENT
MCL -8: Eight – output Zone expander
RL - 8: Eight – relay interface unit.

 

 